Cross-shaped negative pressure
This pioneering design is more in line with ergonomics,making the operation of negative pressure suction stone more conveniect.
-
Passive bending
Flexible-Y front end facilitates to passively bend via endoscope to observe the stone in narrow renal calyx and improve visual field
-
Detachable Design
The sheath tube and the negative pressure connector are designed to be detachable. This pioneering design can adjust the angle of the negative pressure joint at will according to the human bady position or operation habits,which brings higher convenience to the operation
Special Designed for More Efficient RIRS Surgery
Pressing the air hole on the cross-shaped connector with your finger allows you to intuitively feel the suction, making it more convenient to perform negative pressure stone removal.
Cross-shaped detachable design
The sheath and cross negative pressure joint feature a detachable design, allowing the angle of the cross negative pressure joint to be adjusted according to the body position or operational habits.
Flexible Tip Sheath
Hydrophilic coating and Flexible tip sheath support surgeon smoothly access through the renal pelvis during RIRS.
Visualized Stone Clearance
Press the finger to control the air holes on the cross-shaped connector, and expel the stones from the body.
From Access to Complete Stone Management
Traditional Guide Sheath
The sheath serves only as a channel for the instrument to enter.
ZSR Complete RIRS solution
Flexible access combined with IRP sensing point, Visualized Stone Clearance and intelligent fluid management.
ADVANCED NAVIGATION TECHNOLOGY
Key Features
Hydrophilic Coating
Hydrophilic coating at both inner and outer tube to avoid damage to uninary tract.
Seamless Transition
The seamless transition between the sheath and the connector creates a smooth pathway, enabling smooth advancement of the flexible ureteroscope.
Flexible Tip Design
The flexible tip design passively bends to assist doctors in more smoothly entering the renal pelvis.
Stone Clearance
By controlling negative pressure to remove stones through pressing, the detachable design allows the cross negative pressure joint to be adjusted to the required angle according to the body position or operating habits.
One Platform.
Complete Stone-Free Solution.
ZSR Integrates Digital ureteroscope, flexible access and intelligent fluid management into one complete ecosystem.
Digital
Ureteroscope
Explore ZSR Complete RlRS Solution
Discover advanced visualization, flexible access and intelligent fluid
management solutions for next-generation stone treatment.